Min.
300A Elect.
Service Req.
| Model |
|
Tempra™ 12 |
Tempra™
15 |
Tempra™
20 |
Tempra™
24 |
Tempra™
29 |
Tempra ™
36 |
| Phase |
|
1 |
1 |
1 |
1 |
1 |
1 |
| Voltage |
V |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
208 |
240 |
| Wattage |
kW |
9 |
12 |
10.8 |
14.4 |
14.4 |
19.2 |
18 |
24 |
21.6 |
28.8 |
27 |
36 |
| Amperage |
A |
44 |
50 |
52 |
60 |
70 |
80 |
88 |
100 |
105 |
120 |
132 |
150 |
| Min.
required circuit breaker size |
A |
60 |
60 |
2
x 40 |
2
x 40 |
2
x 50 |
2
x 50 |
2
x 60 |
2
x 60 |
3
x 50 |
3
x 50 |
3
x 60 |
3
x 60 |
| Recommended
wire size |
AWG
COPPER |
6 |
6 |
2 x 8 |
2 x 8 |
2
x 8 |
2
x 8 |
2 x 6 |
2
x 6 |
3
x 8 |
3
x 8 |
3
x 6 |
3
x 6 |
| Maximum
temp. increase |
@1.50
GPM |
41 |
54 |
49 |
65 |
66 |
88 |
82 |
92 |
92 |
92 |
92 |
92 |
| above
ambient water temp. |
@2.25
GPM |
27 |
36 |
37 |
43 |
44 |
58 |
54 |
73 |
66 |
87 |
82 |
92 |
|
|
@3.00
GPM |
20 |
27 |
25 |
33 |
33 |
44 |
41 |
54 |
49 |
66 |
61 |
82 |
| |
@4.50 GPM |
- |
- |
- |
- |
22 |
29 |
27 |
37 |
33 |
44 |
41 |
55 |
| Min.
water flow to activate unit |
GPM / Lmin |
0.29
/ 1.1 |
0.58
/ 2.2
|
0.58
/ 2.2 |
0.58
/ 2.2 |
0.87
/ 3.3 |
0.87
/ 3.3 |
| Weight |
Lb
/ Kg |
15
/ 6.8 |
18
/ 8.1 |
21
/ 9.5 |
18
/ 8.1 |
24.25
/ 11 |
24.25
/ 11 |
| Nominal
water volume |
Gal / L |
0.13
/ 0.5 |
0.26
/ 1.0 |
0.26
/ 1.0 |
0.26
/ 1.0 |
0.39
/ 1.5 |
0.39
/ 1.5 |
| Width |
inch
/ cm |
14 9/16
/ 37
|
21
3/4 / 55.2 |
21
3/4 / 55.2 |
| Height |
inch
/ cm |
|
| Depth |
inch
/ cm |
4
5/8 / 11.6 |
| Working
pressure |
PSI
/ BAR |
150
/ 10 |
| Tested
to pressure |
PSI
/ BAR |
300
/ 20 |
| Water connections
|
|
3
/ 4" NPT |
|